GR40CW

Retrofit Radiography

The Samsung GR40CW offers a seamless upgrade from CR to DR, enhancing workflow efficiency with rapid image acquisition and advanced diagnostic tools. Compact and user-friendly, the GR40CW integrates easily with existing equipment, delivering superior image quality for improved patient care.
DR-GR40CW-Hero-450x600

Enhanced Workflow

GR40CW allows users to simplify their daily routines. With GR40CW, workflow is three times faster than with CR systems and GR40CW is the same size as film/CR cassettes, allowing you to upgrade your old equipment to DR system without unnecessary hassle. Auto Exposure Detection (AED) recognizes exposure timing automatically without a cable connection between the X-ray generator and detector, thus enabling simple installation. By reducing workflow steps, it reduces cost and time while increases productivity.

cafa9f63-8635-407b-89da-ce05d418aeda

Intuitive User Interface

Intuitive User Interface

The workstation's intuitive interface enables users to easily operate the system. Anatomical Programmed Radiography (APR)_, selects the appropriate imaging method forthe areas being imaged to help ensure quick examinations.
Fast Preview

Fast Preview2

Preview and acquisition take less than 2 seconds, and a full acquisition less than 6 seconds. It is easy to shoot multiple images after checking the preview image. 
Manual Stitching

Manual Stitching1

Manual Stitching can capture a body part that is larger than the detector area. After taking multiple images, the Align-Assist function makes the alignment process easy, which helps merging them into one image. For example, a surgeon can check the whole spine image right after spine surgery with Manual Stitching.
Mirror View

Mirror View1,3

In the ER/OR or trauma environments, Mirror View provides secured screen sharing for quickly acquiring and checking images in real-time. This function supports medical staff to check images together on a separate screen, reducing first aid response time and the risk of contamination.
S-Share (1)

S-Share1

S-ShareTM can dramatically increase efficiency through the use of the AccE Glass-Free Detector or AccE Standard Detector with various existing compatible equipment. It enables accelerating connection for better synergy with premium digital radiography systems. 

Reliable in a Versatile Environment

usa-samsung-dr-gc85a-vision-std-frnt-bk

GR40CW with Standard Detector

To optimize image quality, Samsung introduces AccE Standard Detector, expanding choices of CsI detectors. This lineup meets various clinical needs with multiple sizes. Enhanced load allowance and dust and water resistance ensure versatility in environments like the ER and OR.

Low dose in S-Vue™

S-Vue™ not only provides excellence in image quality, but also secures better x-ray radiation and improves patient satisfaction. The dose level can be reduced up to 45% dose reduction for pediatric abdomen, 15.5% for pediatric chest, and 27% for pediatric skull exams with advanced denoising algorithm.
Pediatric Chest PA
Case 1. Pediatric Chest PA taken with GM85
Pediatric Abdomen PA
Case 2. Pediatric Abdomen PA taken with a GC85A
Adult Chest PA
Case 3. Adult Chest PA taken with a GC85A

Diagnostic Confidence

Intelligent support with advanced applications allows radiologists to see more details and assist to make clinical decisions confidently. Easy to use applications with one click facilitates fast and efficient daily exams. 

Request More Info or Schedule a Demo

  • This page includes on-screen contents simulated for illustrative purposes. Actual UI may vary depending on software version, region, and other factors.
  • The claim concerning Samsung DR is based on limited phantom and clinical study results. Only routine PA chest radiography and abdominal radiography for average adults and pediatric abdominal, chest, skull radiography were studied, excluding pediatric patients under 1 month old.(FDA cleared - K172229, K182183)In practice, the values of dose reduction may vary accordingly.
  • Clinical images calculates the dose reduction rate from its own standard dose at the clinical site, unlike our FDA claim which compares dose between new IPE and old IPE. The clinical site is responsible for determining whether the particular radiographic imaging needs are not impacted by such x-ray dose reduction. These are clinical dose reduction cases and rates may vary by the exposure condition of hospitals.
  • Clinical images are clinical dose reduction cases and rates may vary by the exposure condition of hospitals.
  • The described product information, including features and options, is CE marked. Regulatory approval/clearance status may vary by country.
  1. Optional feature requiring additional purchase
  2. Fast Preview
    - Image acquisition time may vary according to the image processing parameters and detectors.
    - Fast preview time using AccE Detector (S4343-AW, S4335-AW, S4335-AWV), AccE Standard Detector (S4343-AWM, S4335-AWM)
  3. Mirror View:
    - Compatible with Windows 10 only
    - Miracast receiver dongle is necessary.
    - When using the Mirror View, image transmitted via Miracast is not available for the purpose of diagnosis.
  4. ALND cannot be used on the patients who have lung lesions other than abnormal nodules and was not tested on images having more than three nodules.